Data sheet US2:18HUG82BF
Non-reversing motor starter Size 3 Three phase full voltage Solid-state
overload relay OLRelay amp range 25-100A 110V 50HZ / 120V 60HZ coil
Combination type 125Amp circuit breaker Enclosure NEMA type 1 Indoor
general purpose use Extra-wide enclosure
product brand name
Class 18 & 26
design of the product
Full-voltage non-reversing motor starter with motor circuit protector
special product feature
ESP200 overload relay
General technical data
Height x Width x Depth [in]
36 × 24 × 8 in
touch protection against electrical shock
NA for enclosed products
installation altitude [ft] at height above sea level maximum
6560 ft
ambient temperature [°F]
● during storage
-22 ... +149 °F
● during operation
-4 ... +104 °F
ambient temperature
● during storage
-30 ... +65 °C
● during operation
-20 ... +40 °C
Horsepower ratings
yielded mechanical performance [hp] for 3-phase AC
motor
● at 200/208 V rated value
25 hp
● at 220/230 V rated value
30 hp
● at 460/480 V rated value
50 hp
● at 575/600 V rated value
50 hp
Contactor
size of contactor
NEMA controller size 3
number of NO contacts for main contacts
3
operating voltage for main current circuit at AC at 60 Hz
maximum
600 V
operational current at AC at 600 V rated value
90 A
mechanical service life (switching cycles) of the main
contacts typical
5000000
Auxiliary contact
number of NC contacts at contactor for auxiliary contacts
0
number of NO contacts at contactor for auxiliary contacts
1
number of total auxiliary contacts maximum
7
contact rating of auxiliary contacts of contactor according
to UL
10A@600VAC (A600), 5A@600VDC (P600)
Coil
type of voltage of the control supply voltage
AC
control supply voltage
US2:18HUG82BF
Page 2/3 1.14.2021 Subject to change without notice
© Copyright Siemens
● at AC at 50 Hz rated value
110 V
● at AC at 60 Hz rated value
120 V
holding power at AC minimum
14 W
apparent pick-up power of magnet coil at AC
310 V·A
apparent holding power of magnet coil at AC
26 V·A
operating range factor control supply voltage rated value
of magnet coil
0.85 ... 1.1
percental drop-out voltage of magnet coil related to the
input voltage
50 %
switch ON delay time
26 ... 41 ms
OFF delay time
14 ... 19 ms
Overload relay
product function
● overload protection
Yes
● phase failure detection
Yes
● asymmetry detection
Yes
● ground fault detection
Yes
● test function
Yes
● external reset
Yes
reset function
Manual, automatic and remote
trip class
Class 5 / 10 / 20 (factory set) / 30
adjustable current response value current of the current-
dependent overload release
25 ... 100 A
make time with automatic start after power failure
maximum
3 s
relative repeat accuracy
1 %
product feature protective coating on printed-circuit board
Yes
number of NC contacts of auxiliary contacts of overload
relay
1
number of NO contacts of auxiliary contacts of overload
relay
1
operational current of auxiliary contacts of overload relay
● at AC at 600 V
5 A
● at DC at 250 V
1 A
contact rating of auxiliary contacts of overload relay
according to UL
5A@600VAC (B600), 1A@250VDC (R300)
insulation voltage
● with single-phase operation at AC rated value
600 V
● with multi-phase operation at AC rated value
300 V
Enclosure
degree of protection NEMA rating
1
design of the housing
Indoor general purpose use
Circuit Breaker
type of the motor protection
Motor circuit protector (magnetic trip only)
operational current of motor circuit breaker rated value
125 A
adjustable current response value current of
instantaneous short-circuit trip unit
500 ... 1250 A
Mounting/wiring
mounting position
Vertical
fastening method
Surface mounting and installation
type of electrical connection for supply voltage line-side
Box lug
type of connectable conductor cross-sections at line-side
at AWG cables single or multi-stranded
1x (10 AWG ... 1/0 AWG)
temperature of the conductor for supply maximum
permissible
75 °C
material of the conductor for supply
AL or CU
type of electrical connection for load-side outgoing feeder
Box lug
tightening torque [lbf·in] for load-side outgoing feeder
120 ... 120 lbf·in
type of connectable conductor cross-sections at AWG
cables for load-side outgoing feeder single or multi-
stranded
1x (14 ... 2/0 AWG)
www. usa.siemens.oomficcala\og
hllus:/Ima\|.Indusll'v.siemens.comlmalIlen/us/Cala|0q/Dmducl’.’m\fb=U52:18HUGSZBF
hllgs Isupgo dusty emensDom/csIUS/enlpslUS 18HUGSZBF
hllu:llwww.automalion.siemens.comlhilddh/cax de.aSnx?m|fb=U52:18HUGSZBF&Ianq=en
hllus:Us“DUOI1.induslrv.siemens.oomlcslUS/en/DSIUSZ:18HUGSZBFIDenifIcaKe
US2:18HUG82BF
Page 3/4 1.14.2021 Subject to change without notice
© Copyright Siemens
temperature of the conductor for load-side outgoing feeder
maximum permissible
75 °C
material of the conductor for load-side outgoing feeder
AL or CU
type of electrical connection of magnet coil
Screw-type terminals
tightening torque [lbf·in] at magnet coil
5 ... 12 lbf·in
type of connectable conductor cross-sections of magnet
coil at AWG cables single or multi-stranded
2x (16 ... 12 AWG)
temperature of the conductor at magnet coil maximum
permissible
75 °C
material of the conductor at magnet coil
CU
type of electrical connection for auxiliary contacts
Screw-type terminals
tightening torque [lbf·in] at contactor for auxiliary contacts
10 ... 15 lbf·in
type of connectable conductor cross-sections at contactor
at AWG cables for auxiliary contacts single or multi-
stranded
1x (12 AWG), 2x (16 ... 14 AWG), 2x (18 ... 16 AWG)
temperature of the conductor at contactor for auxiliary
contacts maximum permissible
75 °C
material of the conductor at contactor for auxiliary contacts
CU
type of electrical connection at overload relay for auxiliary
contacts
Screw-type terminals
tightening torque [lbf·in] at overload relay for auxiliary
contacts
7 ... 10 lbf·in
type of connectable conductor cross-sections at overload
relay at AWG cables for auxiliary contacts single or multi-
stranded
2x (20 ... 14 AWG)
temperature of the conductor at overload relay for auxiliary
contacts maximum permissible
75 °C
material of the conductor at overload relay for auxiliary
contacts
CU
Short-circuit current rating
design of the short-circuit trip
Instantaneous trip circuit breaker
breaking capacity maximum short-circuit current (Icu)
● at 240 V
100 kA
● at 480 V
100 kA
● at 600 V
25 kA
certificate of suitability
NEMA ICS 2; UL 508; CSA 22.2, No.14
Further information
Industrial Controls - Product Overview (Catalogs, Brochures,…)
www.usa.siemens.com/iccatalog
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:18HUG82BF
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/US/en/ps/US2:18HUG82BF
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:18HUG82BF&lang=en
Certificates/approvals
https://support.industry.siemens.com/cs/US/en/ps/US2:18HUG82BF/certificate
THREE PHASE
10 SUPPLY
‘L1 L2 L3 ‘
| | I
DISCONNECT
CIRCUIT BREAKER
B A
/ ALTERNATE
X CONNECTIONS FOR
J: TRANSFORMER
v M w
I CONTROL FUSES
2 (OPTIONAL)
T1 T2 T3
OVERLOAD RELAY SEC FUSE
95 I—‘Nq 96 H4 x1
Y 1‘
T2 SEC
M x2
T1 13 1“